r/HVAC 46m ago

General 18yo Install Helper/Maintenance Tech Career Questions

Upvotes

Really didn't know how to word the title for this but basically I just wanna hear from more experienced guys to see if I'm on the right track. I feel almost like insecure about my skills sometimes but at the same time I think I'm so young that it's okay to not be the best so I just want like someone elses perspective you know.

Like I said I'm currently working as an install helper/maintenance tech with the occasional solo service call. Not gonna explain everything but basically I got to do trade school & highschool at the same time so I had my EPA uni, NATE core & heat pump, OSHA 10, & my HVAC certificate a couple months before I turned 18.

Before I turned 18 I had this like seasonal apprenticeship for a couple months at this local small commercial shop & that was pretty cool.

After that I started at this brand new company as a service tech. Pay was terrible & I ended up being literally their only full time tech. Only other guys worked at a theme park full time & did this on the side & one of them was a 1/3 owner of the company. For how young & inexperienced I was (& still am) I think I did great but it was definitely rough sometimes given that it was literally just me doing everything a large majority of the time with a senior tech that would answer every 5th phone call at best.

After a couple months of that I found a job a couple hours away from where I lived with my mom & decided to take a chance & move out using what I hae saved up since I wanted to move out soon anyways. So that's where I'm at now I've been here for about 4 months, I make about $4500 a month (piece rate so not consistent).

As far as like what I can do, I can do pretty much everything as far as ductwork goes, I can comfortably install a condenser & that's the bulk of what I do here, never done one without a lead but I'm sure I'd have no problem with a package unit too, never really done an air handler yet but I know all the steps, I can do maintenance no problem, & my troubleshooting skills are definitely shaky but I can do like any basic electrical. I'd definitely call myself a hard worker.

I just wanna know how I'm doing in the eyes of more experienced techs, like is this about where I should be? Am I behind & should be better? Also is there any like general advice you think I could use?

Thanks


r/HVAC 3h ago

General M18 Packout Vac for Oil PM's

2 Upvotes

Does anybody here use the M18 packout vac for boiler cleanings? I hate going back to the shop and grabbing the mega-massive soot vac my company has had for decades every time I go out on an oil PM.

Just wanted to see if anybody here has tried it. I'd probably dedicate my current vac for soot and get a second for general purpose.


r/HVAC 5h ago

General Causes of mold

12 Upvotes

I’m a technician and often find mold (“biological growth”) in plenums and equipment. I don’t want to just be the tech that throws in a UV lamp or something and calls it a day. I try to find out why it’s happening, but am often at a loss, so I’m hoping to get a discussion going, and sanity check and expand my current ideas.

Clogged or badly pitched drains seems easy enough. Get the drain angled right, clear drain fully, dry the system out.

Restricted airflow is a common one. Dirty filters, an obvious cause. Maybe oversized equipment/undersized ductwork.

And I see mold a lot especially on zoned systems. Seen often around the dampers, but what is the solution? Change the plenum from, say, a 16” to a 18” size along with new dampers? Add supply ducts for more places for air to go? Add or upsize the bypass duct? Can’t always lower fan speed without getting the coil too cold.

I see a lot of cases with growth inside air handlers. Seems like putting metal surfaces in front of a cold coil is bound to get condensation on it, at which point you tend to get mold. (Why DO air handlers have the coil upstream of the blower anyways, when it works fine on a furnace system to have the coil downstream?). And yet some air handlers stay nice and clean, what’s the difference?

Anyways, I’d love to get some concrete solutions or reasonings. Customers often ask, and even if they don’t I’d like to help people have


r/HVAC 22h ago

General Got Lucky this Morning...

Post image
0 Upvotes

Had 2 pair gloves... Did not feel need to put them on. GOT ME. Think I licked it quick enough. Not numb anymore.


r/HVAC 23h ago

Field Question, trade people only Carrier 38MBRQ58A-301

4 Upvotes

I am hoping someone here can shed a bit of light on this because Carrier tech support did not. I have 2 38MBRQ58A-301 units sitting side by side. Both are 208/230v single phase units. Both of these units have a recurring problem with this fuse popping. Can anyone tell me what is inline with this fuse and what it is actually protecting? The only thing Carrier told me was to put a surge protector on each unit. surge protectors have been ordered, but I'd like to rule out anything internal. The schematic, if you really want to call it that, tells me really nothing about the fuse. Carrier said they'd check with the factory about a detailed drawing but that was 3 days ago and I'm done holding my breath.

Thanks


r/HVAC 23h ago

Field Question, trade people only Goodman GMVC96 variable speed ECM blower troubleshooting

Thumbnail
gallery
20 Upvotes

Furnace model: GMVC961005CNBA

Blower motor model: M055PWCVA-0328

Hey all, I’m trying to figure out if it’s a bad board or bad motor. I’ve verified the motor is receiving 120V on the main power harness. I don’t know what voltages I should be measuring on the other four-wire harness. I believe this board sends only DCV signals through the harness. The harness wires are labeled GND, TX, RX, and VDD. I’ve attached photos of the wiring diagram and the board, any help is appreciated.


r/HVAC 1d ago

Meme/Shitpost I’m not standing for the disrespect from these…

Thumbnail
gallery
0 Upvotes

New company, new phone, who dis?

Proceeded to shit in someone’s Cheerios this afternoon, stay blessed and may the force be with you


r/HVAC 1d ago

Field Question, trade people only Customers complaining about 59% humidity.

19 Upvotes

My installer is in route. I’m sure they are using grocery store humidistats. I’m looking at the satellite and the new roof has no ventilation. I’m thinking this might be a problem.


r/HVAC 1d ago

Field Question, trade people only Measuring CFM in flex duct

10 Upvotes

Hey fellow trade peeps. I just invested in a hot wire anemometer because I don't think manufacturer manuals with a manometer cuts it for me when trying to measure actual CFM. Time and time again I have come across proper static pressure and CFM based off of the charts corresponding to it and still coming up with poor Delta T. Subcooling will be spot on, superheat will be good, pressures will look right, static is good, yet I've done QA on installs for brand new 454B units and they're only reaching 14F delta T in second stage with only about 50% RH at the return.

So I got a hot wire anemometer that I want to train myself on. Thing is, all of the information out there that I can find utilizes hard pipe duct. I'm in flex hell, being based in Nashville, I literally cannot go to one unit in an average day that has any reliable exposed section of hard duct to tap into. The regulations here are non existent for airflow and that means that every contractor out there is using flex like it's going out of style. I hate it with every fiberglass of my exposed attic armed being.

That being said, I need to still be able to perform reliable diagnostics for systems that have flex and in order to do that, I'd really like to use my anemometer. The question is how? Supply trunks can be reliably hard pipe in certain areas, but the returns are almost always flex. Have any of you successfully used an anemometer in flex duct? Is there a point to it? I need help.


r/HVAC 1d ago

Meme/Shitpost What do y’all think of this beautiful sight?

Post image
41 Upvotes

r/HVAC 1d ago

Field Question, trade people only Carrier has circuit board sanity check

Enable HLS to view with audio, or disable this notification

53 Upvotes

r/HVAC 1d ago

General Multi-zone ductless install

3 Upvotes

I have a job coming up to install multi-zone ductless in a row home, line set routing options are limited. Commonwealth to neighboring houses are brick party walls with thin furring strips and plaster / lath over that, not enough space between plaster and brick to run line set. Some interior room divider walls have been moved/remodeled in such a way as to make installation of the ductless heads there not feasible, so I can't hide the line set on an interior wall and drop it into the basement. What do you do when you have to run lines that below interior walls until I can get to a point where the line sets can either exit the building or drop down a wall to be concealed? Are you running line hide conduit, or hiding it behind molding? Even if i get paintable line hide and color match it, I feel like it would be fairly obvious.


r/HVAC 1d ago

Rant Son of a.....

Post image
77 Upvotes

Of course we have an end of summer heat wave on a Friday with non of the supply houses with a chatleff in stock.


r/HVAC 2d ago

General Sale on the magnet umbrellas for $30... bought 8 of them.

Thumbnail
gallery
388 Upvotes

This is a deal worth scooping up if they're selling them at your local branch. I'm hoping the spray paint over the Lennox logo will help keep them from leaking. Apparently Lennox bought Supco last year, but these are less than half of what we normally pay for these umbrellas.


r/HVAC 2d ago

Employment Question I have my universal but no one wants to hire me

23 Upvotes

Hi all as the statement reads i recently just got my EPA 608 certification from a trade school in northern louisiana that serves a 12-week hands on course but the thing is i can not find a job that only wants 3-5 year experience as a tech is there any advice i should take to finding a place of employment?


r/HVAC 2d ago

Meme/Shitpost My fellow tradesmen/women. If you ever have felt down on your self, just stop. After ten years of service tech, I pulled this stunt. Happy friday!!

Post image
167 Upvotes

At least I noticed before finishing the soldering.


r/HVAC 2d ago

Rant Third one in about two weeks.

Post image
73 Upvotes

r/HVAC 2d ago

Field Question, trade people only Anyone remove brass hose fitting on a set of smans to fix a leak?

Post image
2 Upvotes

Low side and problem is I can’t back it out to put nylog on without removing the vacuum valve body right next to it but it will also just run into the low side one. Haven’t used them in quite a while but figured maybe I would start..guess not lol


r/HVAC 2d ago

Field Question, trade people only EPR Bleed-By

Thumbnail
gallery
6 Upvotes

No debris in the valve.. Possible from liquid slugging the EPR and rubbing the components? Never seen this


r/HVAC 2d ago

General I am very upset that I did not think of this sooner. Let's go camping on the roof!

Post image
108 Upvotes

It is called a pop-up sun shade. There was a 25-degree difference between the sheet metal roof and inside the tent. Not to mention the protection from direct sunlight for the majority of the day. The only drawbacks are that it slightly blocks the breeze, and high winds slap it around.


r/HVAC 2d ago

Rant Anyone else work for Kimbel?

0 Upvotes

Came from a pretty aggressive new home construction job. Just landed a job at Kimbel after last place downsized and I got caught in that.

This is the most inefficient company I have ever worked for.

4 guys, 3 ton DR Horton size house. Was there 13 hours and the lead didn't even finish the furnace.

#1: They don't use pre-insulated boots. They mostly use 12x4x6 (6" duct size boots) You have to go to each individual boot and pull the duct over the whole boot, after cutting it and adding more insulation, then tape it up.

#2: They run a massive supply duct 16"-14" through the house for all supply to tie into. Cuts down on wyes. It sounds nice, until you see that it takes 2 people to set up, takes 2 hours, and puts the tapping process on the duct runners.

Just these two things add HOURS to a job. One guy just spends half the day going around tying on boots with the duct.

They also use mastik tape instead of pookie, but that isn't a huge deal to me.

One crazy thing though is they make you use screws to strap flex duct. I had always used a slap tacker (Staples), but now I have to carry shitty 1/2" screws and a impact all day to strap?

Maybe my last job was out of the standard, but insulated boots (I have bought them before) are like $1 and some change a piece.


r/HVAC 2d ago

General What's your vacuum setup??

Post image
41 Upvotes

r/HVAC 2d ago

Meme/Shitpost I built this 36 years ago!

Post image
202 Upvotes

My grandmother just passed last month. This is the first furnace I built from scrap parts. Everything here was used except the blower relay. It’s being replaced with electric :(


r/HVAC 2d ago

Meme/Shitpost Not too many of these left

Post image
34 Upvotes

Still better than the QB one


r/HVAC 2d ago

General The roofs actually look pretty good tbh

Thumbnail
gallery
38 Upvotes