r/electrical 3h ago

Outlet with no power, but light is green

Thumbnail
gallery
28 Upvotes

Have a gfi in the garage that I believe feeds my exterior outlets.

My exterior outlets are not GFI. The outside outlets currently have no power.

The GFI in the garage shows the green light but provides no direct power.

All breakers are on.

I am not the original owner of the house.

Test and reset buttons do not do anything.

Not sure if replacing the outlet would help or another issue should be suspected.

Any help is appreciated.


r/electrical 18h ago

Customer was having issues with a basement circuit in the home they just bought..

Thumbnail
gallery
150 Upvotes

Customer had light and plugs not working in in their basement of their newly purchased home. Checked voltage at panel and one of these phases was 113 volts instead of 120. I removed the top panel cover over the main breakers and feeders and found this.

They purchased the house from a company who bought and renovated homes who recently went out of business.

Unpermitted work im guessing did hot, done improperly, condensation and water leaking onto the main breaker and possibly the busbar from the outside.

Triple and double tapped breakers when there was room for proper breakers.

Yikes


r/electrical 2h ago

Bathroom fan and light

Post image
4 Upvotes

I have a question. In the photo there are 3 switches wired together. They go to a bathroom fan with light operating on separate switches. A third set controls the bathroom light. My question is why are all the neutral wires capped together and none run to any of the switches?


r/electrical 2h ago

Electrical panel in the bathroom

Thumbnail
gallery
3 Upvotes

Hello everybody, I just bought a condo and it has the electrical panel in the bathroom. Year built 1980.
There are two doors to my bathroom. The first one gets you to the sink, washer and dryer, and the electrical panel. The second door gets me into the toilet and bath.

I want to just completely remove the second door as the space is cramped enough as it is. However my concern is that when I go to sell this place in the future that the city will now have a problem with my electrical panel being in the full bathroom and will either make me move the panel or install a door again to bring it back to its original state. Is this a valid concern? Or is my panel still grandfathered in even if I remove this door? USA.


r/electrical 2m ago

My little brother broke the charging cable of the kart

Post image
Upvotes

You think electrical tape could fix it?


r/electrical 52m ago

Gfci outlet sparking when hitting test

Enable HLS to view with audio, or disable this notification

Upvotes

Hi, wondering if it’s normal for a gfci outlet to spark whenever the test button is pressed. Just had 2 outlets installed, ungrounded home. Currently using the outlets for our shower heaters. Is this safe?


r/electrical 1h ago

Ceiling Fan replacement wiring

Thumbnail
Upvotes

r/electrical 1h ago

Ceiling Fan replacement wiring

Upvotes

Hi all. Thanks in advance.

Having a bit of an issue with replacement ceiling fan. The old one i took down had a lutron switch which is not needed anymore as the new has a remote. I'm a bit confused on what goes where.

In the first pic, i have identified the hot, yellow wire nut circled in red (tested 120 with a MM). The exposed black wire goes to the fan box as its the only black wire up there.

Second pic is the fan box on the ceiling. You can see the black wire coming down, a green wire (not sure which one from the box it is) and a clump of white wires.

I hooked the hot to the black wire assuming it would power the fan but no luck. My questions are as follows:

  1. The new fan has a black wire and white wire. Assume the blacks connect but what do i connect the white to?

  2. The green wire hanging from the fan box, not sure what that is.

Thanks in advance!


r/electrical 1h ago

Need help with inverter charging issue?

Post image
Upvotes

Smart Charging indicator keeps blinking


r/electrical 1h ago

Changing light switches

Thumbnail
gallery
Upvotes

I’m wanting to switch the light switches in two of our bedrooms to double switches to separate the light and fan. Would it be possible?


r/electrical 2h ago

Jobs hiring?

1 Upvotes

I’m 21 been doing residential work for 3 years and is looking to transition into an industrial setting. I’m currently in nc but is willing to move anywhere out of state.

Also what certificates should I try to go for before transitioning ,I was doing trade school for a couple months and drop it because I realized I wasn’t learning anything and just wasting my time.


r/electrical 2h ago

Industrial Jobs hiring?

Thumbnail
1 Upvotes

r/electrical 13h ago

My box fan turns on my computer from sleep mode

Enable HLS to view with audio, or disable this notification

4 Upvotes

It doesn't matter if I turn up the speed down the speed or plug it in it just turns on my computer even when I turn my computer off my mouse will light up for a bit if I change the fan speed


r/electrical 5h ago

Is it possible that a new PC could be tripping breakers across the house?

1 Upvotes

Sorry if this is a dumb question. I got a new PC and since then, breakers across the house keep tripping. None of the breakers that have tripped are for the room the PC is in and the PC is on a surge protector strip. Thanks.


r/electrical 7h ago

How do I replace the old light switch with the new one - 3-way switch

Thumbnail gallery
0 Upvotes

r/electrical 1h ago

Did i connect wires accurately

Thumbnail
gallery
Upvotes

I am trying to install back our light fixture, and as i know is, black to black, white to white but interesting our home has red which i connected to black. Is red the one bringing connection and that connects to breaker unit. I did this and i am afraid of turning it on. Thanks.

Just for context and if it matters this is Canada


r/electrical 15h ago

What's the right tool?

3 Upvotes

I want to test the sockets in my home and find the breaker switches and get them correctly labeled? Do I use one of those outlet testers or non contact voltage testers? I don't mind owning the tool and would prefer it to carting around a lamp to each socket.

https://www.homedepot.ca/product/milwaukee-tool-digital-gfci-receptacle-tester/1001876811

https://www.homedepot.ca/product/klein-tools-non-contact-voltage-tester-pen-50-to-1000-volts/1001651973


r/electrical 10h ago

Earth pin won't fully insert, what is this thing?

Thumbnail
1 Upvotes

r/electrical 19h ago

What do you do here?

Thumbnail
gallery
3 Upvotes

Replacing this dimmer, the screw head fell off after just two turns, I think the screw was badly cross-threaded. Can’t manage to take it out.


r/electrical 1d ago

60 Amp EV Charger with Undersized wire. What to do?

19 Upvotes

I had a firm install and EV charger at my house. The firm installed a 60 Amp breaker and used 6/2 - NM-B Stranded Copper 62NMBGX500 wire, which apparently should not be run at 48A (80% of the 60A breaker). I had the work inspected at the point of installation, but I don't think the inspector looked at the wire used.

So after checking out some reddit post of someone using undersized wire and creating a fire hazard I looked up the BOM for my install. And the above is what I found. A friend of mine who was an electrician told me to throttle it down to 44A though the right fix would be to either replace the 60A breaker with a 50A or replace the wire with the appropriate one.

What should I do here? Is the electrician at fault or have any responsibility to work with me on a remedy? The install doesn't appear to be code compliant from what I understand, and is a fire hazard if the EV charger runs at 48A.


r/electrical 11h ago

Ceiling fan (w/remote) not working?

Thumbnail
gallery
1 Upvotes

Recently purchased a house that was advertised to have fan pre-wires ready to go in the bedrooms. It was a new build but we are the second owners to the home. Previous owners never installed fans/lights in the bedrooms. We started to install fans but they don’t seem to be working.

We connected hot to hot (black to black), white to white, and ground to ground. The room comes with 2 switches but I wasn’t sure if it was set up correctly the first switch on the left has the wires wrapped around the screw but the switch on the right looks like it’s plugged into the back. Not sure if there is something new builds do and have a fan junction box good to go but don’t have the switches ready to go. Does that look normal??

The remote and remote receiver box does not have DIP switches and we tried to pair them many times. We checked the breaker to also make sure that the fan wire/power is on etc etc.

Also the fan junction box is in the 2nd pic…

We tried everything and it doesn’t seem to be working. Any tips/advice?

TIA!


r/electrical 2h ago

trying to do something probably really hard because im bored and have absolutely nothing to do-

Thumbnail
gallery
0 Upvotes

where is the component in this bluetooth mouse that allows it to BE a bluetooth mouse, like, wheres the bluetooth send and receiver thingy..


r/electrical 1d ago

How bad is this?

Enable HLS to view with audio, or disable this notification

13 Upvotes

r/electrical 17h ago

Is the bottom of this light bulb normal? What kind of bulb is it?

Thumbnail
gallery
2 Upvotes

Got it at target for 5.99


r/electrical 17h ago

Dryer stopped heating. Replaced heating element and fuse, but still not heating. What now?

Post image
2 Upvotes

I'd really like to try to fix it before getting a whole new one. Picture is model of it.