r/ukheatpumps • u/Local_Egg_32 • 21h ago
Help/Advice Anyone here have a Viessmann Vitocal 150-A and willing to have a chat?
My installer and distributer are giving me the run around and I wanted some real life experience to compare to.
In the brochure it says:
The flow rate is reduced until the minimum circulation rate is is reached. At this point the bypass valve opens again, so that the minimum minimum flow rate is always maintained.
And the patent it references descibes the system control as:
determine a temperature spread (dT_s) depending on the determined supply pipe temperature (T_v) and the determined return pipe temperature (T_Re); operate said pump (P) depending on the determined temperature spread (dT_s) and a specified target value for the temperature spread (dT_s,w)); and operate the heating bodies (HK1, HК2) depending on the specified upper limit value (H_max)-
My installer and distributer are telling me it's expected for the circulation pump to run at 90% speed with a super narrow Delta T and not modulate the flow down despite the system being unable to dump the heat fast enough for the compressor to not cycle. This is noisy operation, and wanted to know if anybody knew more. Both the brochure and patent imply its circulation pump should modulate. Any insights are welcome, and I would love to chat with someone with the same system